Receive
Disassembled Part
Explanation
Through disassembly, parts in a serial structure can be detached and
received to inventory as peice parts, sub-assemblies or partial parts,
making them available for disposition or further disassembly. The received part type can be either
position parts or disassembly products. For any given part, you cannot
receive a combination of both types on a single order. Sub-assemblies that need further
disassembly must be received as disassembly products. A proposed location to receive to
can been set for the shop order. If no proposed location is set, you can
enter a location for each receipt.
Prerequisites
- The shop order must have reached at least the Released
status.
- The disassembly shop order must be completely issued. This means
that any disassemblies on a higher level in the structure must have been
completed.
System effects
If Auto report operations is enabled, operations will be reported automatically.
For received serials:
- The serial will be removed from the serial structure.
- If the received serial is the expected serial based on the serial structure, the part serial catalog structure record will be
updated to reflect the fact that the received serial is no longer
contained in the parent serial.
- In the part serial catalog, the operational status of the received
serial will be set to Out of Operation while its operational
condition remains Operational or Non-Operational .
- In the part serial catalog, the operational condition of the issued
serial will be set to Non-Operational if its operational
condition was previously Operational.
- The current position for the received serial will be set to In
Inventory in the part serial catalog.
- A replacement history record will be created for the received
serial.
- The inventory part location for the received serial will be updated
to the location into which the part is received.
- The actual off-log will be updated with the received serial.
- If the received serial is not what was expected based on the serial structure, an information message will be displayed and a
structure mismatch log record will be created. Note that user will need
to make changes to the serial structure to detach the expected
serial.
- If the received serial is not an existing serial, both a part serial
record in part master and a serial part record in Fleet and Asset Management will be created.