Define Control Plan Template Lines

Explanation

Each control plan template consists of two levels: a header and one or more lines. This activity is used to create new control plan template lines. A control plan template line for manufacturing specifies how a part is going to be inspected when doing a particular routing operation belonging to the routing entered in the control plan header. A control plan template line for purchasing specifies how a purchased part is going to be inspected when purchased from the supplier entered in the control plan header. A control plan template line for inventory specifies how a part is going to be inspected when performing analysis in inventory.

For each control plan template line, the sample size will to be calculated when an analysis is created. To calculate the sample size, an inspection code has to be defined. The inspection type specifies whether the sample size is based on a fixed quantity or a sample percentage of the order size. It is not possible to use Percentage as the inspection type for parts that are used as a production schedule parts.

For acceptance sampling, a system-generated inspection code ‘ACCEPTANCE SAMPLING’ is used, which has a sample percentage of 100%. The actual sample size will be calculated by the system when analysis is created. A control plan template line using the inspection code for acceptance sampling will be automatically connected to an acceptance sampling trigger.

To create a new control plan template line click the new command on the Control Plan Template Lines tab and enter information about the template line. To make it mandatory to attach a media item to the result, enable Media Required. In the Data Type field select Attributes, Variables or Categorical. If the data type is set to Categorical, enter a category ID or use the List of Values (LOV) picker to choose from the available category IDs in the Category field. If the data type is set to Variable, enter information about the tolerance limits in the Outer Min, Inner Min, Nominal Value, Inner Max and Outer Max fields. The nominal value is required, together with either the combination Inner Min/Inner Max or Outer Min/Outer Max. Finally click Save.

Note: If the control plan template contains one or more control plan lines with data type is set to Categorical, a value in the Category Entry Type field must have been selected in the header section to be able to activate the template.

Note: To activate acceptance sampling for a control plan line, use the system-defined Inspection Code ‘ACCEPTANCE SAMPLING’. When activating acceptance sampling for a control plan line, the AQL and Inspection Level values will automatically be set to the default values defined in the Acceptance Sampling Parameters section in the control plan header, but they can be edited. If acceptance sampling is activated for a control plan line with data type Variable, it is also mandatory to set Specification Limits and Standard Deviation values.

Prerequisites

System Effects

As a result of this activity, one or more control plan template lines are created. The inspection code selected in the control plan line, will control the sample size for each data point when the analyses are created. The inspection code selected in the control plan line will control the sample size for each data point when the analyses are created.