Swap Serials

Explanation

This activity is used to swap serials within a serial structure or between two different serial structures.

If access control is established, you can only swap the serials to which you have access. Establishing access control is done by assigning a user to an access group which has been defined in basic data. The access groups are used to extend access to all or selected parts and serials in a structure. When the serials are swapped, the access groups belonging to the selected serials will be changed. Therefore, swapped serials will receive access from its new topmost serial's access.

This activity is actually a combination of two removals and two installations. However, it will be carried out as one integrated activity. All the rules regarding the operational status and configuration that apply to an installation of a serial pertain to this activity. The following example illustrates the meaning of swapping two serials within a serial structure. Note: It is possible to swap serials between two different serial structures as well.

Assume that we have two engines, Engine 01 and Engine 02, that is installed in the same aircraft (they can also be installed in two different aircrafts). Each engine structure has a pump installed in it and an access group assigned to it. See the table below:

Before the serials were swapped
Serial structure Serial installed in the structure Access received from its parent
Engine 01 PUMP - 03 Access Group A
Engine 02 PUMP - 04 Access Group B
After the serials were swapped between two structures
Serial structure Serial installed in the structure Access received from its parent
Engine 01 PUMP - 04 Access Group A
Engine 02 PUMP - 03 Access Group B

The process of swapping the pumps between the serials is as follows:

When Pump 03 is swapped and installed in Engine 02, the access groups for the pump will be changed. After the serials are swapped, Pump 03 will receive Access Group B, and Pump 04 will receive Access Group A.

Depending on your workflow, you can perform this activity by clicking the option Perform Structure Change from one of the following pages.

Following is a description of the information that can be entered in each assistant step.

Step 1 - Structure Change Selection

Step 2 - Structure Change Details

Note: You can also swap serials between two different structures. In this case the values in the Vehicle ID, Top Part Number, and Top Serial Number fields in the Remove or Swap from area and Install or Swap into area will differ.

Prerequisites

System Effects