Create and Maintain Minimum Release Life Information
Explanation
This activity is used to define minimum release life values for an overhaul object. The default minimum release
life value can be changed for each shop visit.
The given minimum release life is used;
- As the required remaining life for all the life limited parts (LLPs) in the structure of the overhaul
object.
- As the default value for the work scope defined for a visit.
- In the conformance check for all LLPs that are not included in the work scope.
Prerequisites
- The customer - overhaul object combination must be defined in the Shop Visit
Defaults page.
- The operational parameters for which minimum release life is to be specified must be defined.
System Effects
- When evaluating the LLP events for a work scope, the default minimum release life is retrieved for the
corresponding operational parameter. The minimum release life together with the calculated remaining life will be
used to indicate serials that have less than the required minimum release life.
- The minimum release applied on the work scope will be used in the final configuration conformance check for
all LLPs not included in the work scope.