Configure format for entering and displaying usage hours
The USAGE_HOURS_AS_DECIMAL configuration parameter determines whether the hours-based TSN and Delta measurements for accrued usage are entered and displayed using decimal values or using hours and minutes on the Create Flight, Edit Flight, and Inventory Details, Historical Usage pages.
Set USAGE_HOURS_AS_DECIMAL to TRUE to enter and display the hours measurements using decimal values. Set it to FALSE to enter and display the hours measurements using hours and minutes.
Note: This
applies to any measurement parameter that uses HOUR (Hours) or HOURS (Operating Hours) as its
engineering unit, regardless of the measurement name. If you're creating a custom measurement
parameter in the MIM_DATA_TYPE table, the following columns must have these values for the
HH:MM format to work:
- ENG_UNIT_DB_ID = 0
- ENG_UNIT_CD = HOUR or HOURS